Management
Time Zone/Summer Time Tab Field Descriptions
You can configure an automatic summer time (daylight savings time) time change.
Configure the following parameters:
Time Zone Name The name of the time zone to be displayed during standard time.
Field Format: Maximum 4 characters and minimum 3 characters (do not use
angled brackets < >)
Time Zone Offset The offset from UTC for your local time zone.
Field Format: Hours hh (valid -12 to +14) and minutes mm (valid 0 to 59
minutes)
Summer Time
Name
The name of the configured summer time zone; this will be displayed during
the summer time setting. If this parameter is not set, then the summertime
feature will not work.
Field Format: Maximum 4 characters and minimum 3 characters (do not use
angled brackets < >)
Summer Time
Offset
The offset from standard time in minutes. Valid values are 0 to 180.
Range: 0-180
Default: 60
Summer Time
Mode
You can configure the summer time to take effect:
z None—No summer time change.
z Fixed—The summer time change goes into effect at the specified time
every year. For example, April 15 at 1:00 pm.
z Recurring—The summer time changes goes into effect every year at same
relative time. For example, on the third week in April on a Tuesday at 1:00
pm.
Default: None
Fixed Start Date Sets the exact date and time in which the IOLAN’s clock will change to
summer time (daylight saving time) hours.
Fixed End Date Sets the exact date and time in which the IOLAN’s clock will end summer time